Interactive Access & Hospitality Credential Utility
RFID card & key fob UID, Wiegand 26/34 & lock chip checker
Eliminate mismatched serial numbers and wrong replacement chips before ordering access cards, key fobs, or hotel credentials. Convert bidirectional 4-byte / 7-byte Hex, 8H10D decimal, and Wiegand 26/34 parity frames—and diagnose which 125 kHz or 13.56 MHz IC your installed reader expects.
Bidirectional UID, 8H10D & Wiegand 26/34 converter
Enter any known value from a reader log, NFC scan app, or printed card face to compute every standard laser-engraving representation.
Computed Wiegand & decimal equivalents
- Hex UID (Normal MSB→LSB)
- A1 B2 C3 D4
- Hex Byte-Reversed (LSB→MSB)
- D4 C3 B2 A1
- 10-Digit 8H10D (Normal)
- 2712847316
- 10-Digit 8H10D (Byte-Reversed)
- 3569595041
- 8-Digit 6H8D (Lower 24-bit)
- 11715540
- Wiegand 26 (FC, Card Number)
- FC 178 · CN 50132 (178,50132)
- 26-Bit Parity Binary (Even · 24b · Odd)
- 0 10110010 1100001111010100 1
- Wiegand 34 / Full Integer Value
- 2712847316 (32-bit WG34)
Diagnose your existing access or hotel lock chip
Scan one working card or key fob with a free smartphone NFC reader app (such as NXP TagInfo) and match its behavior below.
Test both F08 and genuine NXP MIFARE Classic EV1 1K 4-byte NUID
Order 4-byte NUID explicitly—7-byte UID Classic variants alter how legacy Wiegand 26 panels truncate serials.
Confirm MSB vs. LSB byte order against one existing card before bulk laser numbering.
Standard RFID card & key fob numbering formats explained
| Marking Code | Bit / Byte Source | Example (`A1 B2 C3 D4`) | Where Used |
|---|---|---|---|
| 8H10D (MSB Normal) | All 4 bytes (`A1B2C3D4`) → 32-bit unsigned decimal | 2712847316 | USB desktop readers, Chinese/European standalone 125 kHz & M1 panels |
| 8H10D (LSB Reversed) | Reversed bytes (`D4C3B2A1`) → 32-bit unsigned decimal | 3569595041 | Byte-reversed Wiegand 34 & PC/SC keyboard-wedge card readers |
| 6H8D | Lower 3 bytes (`B2C3D4`) → 24-bit decimal | 11715540 | 24-bit legacy controllers & dual-marked TK4100 key fobs |
| Wiegand 26 (3D+5D) | Byte 2 (`B2`=178) as FC + Bytes 3–4 (`C3D4`=50132) as CN | 178,50132 | North American & European Wiegand 26 door controllers |
UID, Wiegand & lock compatibility FAQ
Why does my USB desktop reader output a different 10-digit number than what is printed on the card?
One device is reading the 4-byte UID in normal MSB→LSB order (`A1B2C3D4` = `2712847316`) while the other reverses byte endianness to LSB→MSB (`D4C3B2A1` = `3569595041`). Enter your printed 10-digit number above to verify if byte reversal explains the difference.
What does "0011715540 178,50132" laser-printed on a 125 kHz key fob mean?
Both numbers represent the exact same 24-bit value (`0xB2C3D4`): `0011715540` is the straight decimal conversion (`6H8D` padded to 10 digits), while `178,50132` splits the upper 8 bits (`0xB2` = `178` Facility Code) from the lower 16 bits (`0xC3D4` = `50132` Card Number) for Wiegand 26.
How are 7-byte UIDs (NTAG, Ultralight, DESFire) handled on 26-bit or 34-bit Wiegand readers?
Because a 56-bit (7-byte) UID cannot fit inside a 24-bit (WG26) or 32-bit (WG34) payload without truncation, readers transmit a manufacturer-defined 3-byte or 4-byte subset. Always test 5 physical samples through your installed reader to confirm its exact truncation rule before laser-numbering thousands of cards.
Why did replacement 125 kHz cards fail to encode at our hotel front desk?
Most 125 kHz key fobs sold online use read-only TK4100/EM4200 chips, which work for enrollment-by-ID doors but reject write commands. Hotel front-desk 125 kHz encoders require rewritable T5577 EEPROM chips.
Direct Engineering Inquiry
Need pre-numbered or lock-matched samples? Send your spec to engineering
Submit this short form directly on the page—no separate form page required.